Shared Software Features:
·
Easy-to-use, Windows® based interface and
multitasking capabilities.
·
Integrated, shared database with all other IHS
programs. Includes export capabilities to other common medical databases.
·
Online help at any point in the program at the
press of a key.
·
Built-in system calibration, self-check and system
diagnostics modules.
·
Automatic default parameters allow fast start-up
and testing.
·
User-defined testing protocols for automated data
collection.
·
Automated referral letter generation.
·
Print reports, including patient information and
testing parameters, to any Windows® supported printer.
DPOAE Software Features:
Multiple
Views
View the in-ear stimulation intensities and noise
levels for each DP testing frequency. Graphically
display the entire spectrum for each recorded frequency or view a numerical
table of results.
Customizable
Display
For easy comparison, view data from both ears
simultaneously, or view data from a single ear with a detailed point-by-point analysis.
Automatic
Assessment for Fast Screening
Acquired DP test results are automatically labeled
as PASS or REFER, based on user-defined passing criteria. Base the criteria on SNR and/or absolute DP
SPL level and/or Standard Deviation(s)
of DP above noise floor.
Accessible
Normative Data
Choose to use the supplied normative data or easily
create your own, customized normative data to suit your specific needs. Build norms files for different ages and
gender by defining the expected DP response level, noise floor level and their
respective standard deviations.
Easy Data
Acquisition
Straightforward controls allow you to start, pause
or resume data acquisition by making a single mouse click. User-selectable
testing options can be set to automatically load each time the software is
started.
Unlimited
Control with Scripting
Gain complete control on the testing parameters and
data acquisition and your tests by using the powerful built-in scripting
language. Specify your own testing
frequencies and levels to acquire fine structure DP Grams
Fast Test
Setup
Quickly customize the DP test by choosing start and
ending frequencies and the number of frequencies per octave to test. Define F2:F1 ratio, L1 and L2 stimulus level
and the level of in-ear stimulus correction.
Activate test stopping rules for faster screening.
Built-In
Calibration Module
Single mouse click calibration procedure makes it easy
to calibrate the OAE probe. Also,
calibrate at specific frequencies and clearly view the signal in both the time
and frequency domains. Password
protected, to prevent tampering.
User-defined normative data display region.
Automated, variable artifact rejection based on
measured noise conditions.
TEOAE Software Features:
Multiple Response Displays
View the response in both time and frequency
domains, and the meatal response.
Suppression
Masking Option
Upgrade your hardware to include ipsilateral or
contralateral masking and analyze its effects on the efferent neural system.
Adjustable
Artifact Rejection
Move the artifact rejection level slider to block
out unwanted noise contaminants and obtain optimal quality responses.
Accessible
Test Parameters
Modify the testing parameters, including intensity,
rate and number of acquisition sweeps with a few clicks of the mouse.
Time-Frequency
Plots
Analyze acquired transient data with this powerful
tool to detect spontaneous emissions and noise contaminants. View the response peak amplitude and latency
characteristics for a specific frequency range. Examine responses using the Time-frequency distribution graphs
for the response, noise or SNR.
Spontaneous
OAE
Acquire spontaneous OAE's with a click of a mouse.
Numerous
Stimulus Choices
Perform classic transient otoacoustic emissions
testing, or select pure tones with a variety of envelope choices to fulfill
your testing needs. View the selected
stimulus in both the time and frequency domains.
Available upgrades for Masking and Suppression
Options.
Universal Smart Box Features:
·
Light and portable.
·
Connects to any Windows® computer via a USB Port.
·
Up to four Auditory Evoked Potential recording
channels.
· High frequency option.
· Notched noise masking option.
·
One OAE channel (DP and/or Transient and
Spontaneous).
· High frequency option.
· Suppression option.
·
Optional auditory transducers: OAE probe, insert earphones, bone vibrator,
headphones, sound field (with external amplifier) and/or high frequency
transducers.
·
Upgradeable to include Intelligent Visual
Reinforcement Audiometry (IVRA.), SmartEP and SmartScreener.
Universal Smart Box Jr. Features:
·
Light and portable.
·
Connects to any Windows® computer via a USB Port
·
Up to two Auditory Evoked Potential recording
channels.
·
One OAE channel (DP and/or Transient and
Spontaneous).
·
Optional auditory transducers: insert earphones, headphones, bone vibrator
and/or OAE probe.
·
Upgradeable to include SmartEP and SmartScreener.